V60 Curtain Wall System - the Nelson-Atkins Museum - Steven Holl
Benefits / Characteristics:
- - Double-glazed, thermally broken, double-seal open wept system enhances thermal performance & effectively controls water drainage
- - Thermally enhanced SF-60 channel glass walls can achieve U-value of 0.19 or lower
- - SF-60 seamlessly integrates flat glass IGUs, providing continuous design lines
- - Unique frame design requires the glass be captured at the head & sill only
- - All components (head, sill, jambs) are visually identical for consistent, clean look
- - Accommodates vertical or horizontal glass channel orientation, including a unique unitized horizontal configuration
- - Accommodates all channel glass textures (60 mm flanges)
- - Multiple frame configurations, including all-glass curves (min. radius = 7 ft. (2 m)) & corners
- - Standard finish is 2-coat Kynar Arcadia Silver; custom colors available
- - Supported by industry-leading technical design team
- - Made in USA
Test Results
The V60 System with LINIT Channel Glass has been tested and certified as passing:
- Static air infiltration: ASTM E283 - results: .01 cfm @ 6.24 psf
- Structural deflection: ASTM E330 - results: < L/300 @ 30 psf (pg. 10)
- Static water infiltration: ASTM E331 - results: no leakage @ 15 psf
- Dynamic pressure water infiltration: AAMA 501.1 - results: no leakage @ 15 psf
- Interstory drift: AAMA 501.4 - results: category III performance @ +/- 3.00" displacement from 0.
- Condensation Resistance Factor, in accordance with AAMA 1503-98 is 0.57
- U-Value of the assembled system in accordance with AAMA 1503-98 is 0.50
- Acoustical test performance in accordance with ASTM E90, ASTM E413, and ASTM E1332: STC - 40, OITC - 40
Okapane Channel Glass Insulation:
Benefits / Characteristics:
- Excellent thermal insulation for double-glazed channel glass walls
- Can achieve glass wall U-value of 0.19 (combined with Low-E coating)
- Visible Light Transmission (VLT) of approx. 40%
- Lightweight
- Evenly scatters and diffuses light, minimizes glare
- Excellent sun shading effect
- Impervious to moisture
- Smooth, homogeneous appearance
Details:
Composition:
Miniature acrylic tubes covered by translucent fiberglass sheeting
Applications:
Interior, Exterior
Installation:
Inserts in the cavity of a double-glazed channel glass wall. It is secured with silicone at the top, bottom, and one
continuous side. The material arrives cut-to-size from the factory, and can be easily re-cut in the field to meet job
conditions.
Approximate Dimensions:
Factory cut-to-size; Thicknesses = 5/8” (16 mm), 1′′ (24 mm), 1.25′′ (32 mm), 1.5′′ (40 mm); can be easily cut to size in
the field to meet site conditions
Approximate Weight:
0.25 lbs/ft2 (1.2 kg/m2)
Maintenance:
Okapane insulation is securely inserted and sealed inside the cavity of a double-glazed channel glass wall, and does not
require maintenance post installation.
Performance Characteristics:
Visible Light Transmittance (VLT) = 38% (24 mm Okapane)
Visible Light Transmittance (VLT) = 38% (24 mm Okapane)
U-Value = 0.28 (24 mm Okapane without Low-E) / 0.19 (24 mm Okapane with Low-E)
Solar Heat Gain Coefficient (SHGC) = 0.38
STC Rating = Brings an improvement of 1-2 dB soundproofing
Potential Leed Credit:
EA Credit 1: Optimize Energy Performance
IEQ Credit 7.1: Thermal Comfort
IEQ Credit 8.1: Daylight & Views: Daylight 75% of Spaces
IEQ Credit 7.1: Thermal Comfort
IEQ Credit 8.1: Daylight & Views: Daylight 75% of Spaces
Benefits / Characteristics:
- Excellent thermal insulation for double-glazed channel glass walls
- Can achieve glass wall U-value of 0.19 (combined with Low-E coating)
- Visible Light Transmission (VLT) of approx. 40%
- Lightweight
- Evenly scatters and diffuses light, minimizes glare
- Excellent sun shading effect
- Impervious to moisture
- UV-stable, temperature-stable up to 212°F (100 ° C)
- Self-extinguishing
Details:
Composition:
Glass fibers coated with a UV-stable binding agent
Applications:
Interior, Exterior
Installation:
Inserts in the cavity of a double-glazed channel glass wall. It is hung with factory-installed hook strip, silicone at the top, and continuous transparent tape on one side. The material arrives cut-to-size from the factory, and can be easily re-cut in the field to meet job conditions.
Approximate Dimensions:
Factory cut-to-size, compressible; Thicknesses = 2.75” (70 mm – GL), 4” (100 mm – GL Plus); can be easily cut to size in the field to meet site conditions
Approximate Weight:
0.25 lbs/ft2 (1.25 kg/m2)
Maintenance:
Wacotech TIMax insulation is securely inserted and sealed inside the cavity of a double-glazed channel glass wall, and does not require maintenance post installation.
Performance Characteristics:
Visible Light Transmittance (VLT) = 48% (GL) / 23% (GL-Plus) U-Value = 0.24 (GL) / 0.19 (GL with Low-E) / 0.19 (GL-Plus) Solar Heat Gain Coefficient (SHGC) = 0.43 (GL) / 0.24 (GL-Plus) STC Rating = Brings an improvement of 1-2 dB soundproofing
Testing:
Fire-retardant material with Euro class B1 test certificate
Potential Leed Credit:
EA Credit 1: Optimize Energy Performance
IEQ Credit 7.1: Thermal Comfort
IEQ Credit 8.1: Daylight & Views: Daylight 75% of Spaces
Glass fibers coated with a UV-stable binding agent
Applications:
Interior, Exterior
Installation:
Inserts in the cavity of a double-glazed channel glass wall. It is hung with factory-installed hook strip, silicone at the top, and continuous transparent tape on one side. The material arrives cut-to-size from the factory, and can be easily re-cut in the field to meet job conditions.
Approximate Dimensions:
Factory cut-to-size, compressible; Thicknesses = 2.75” (70 mm – GL), 4” (100 mm – GL Plus); can be easily cut to size in the field to meet site conditions
Approximate Weight:
0.25 lbs/ft2 (1.25 kg/m2)
Maintenance:
Wacotech TIMax insulation is securely inserted and sealed inside the cavity of a double-glazed channel glass wall, and does not require maintenance post installation.
Performance Characteristics:
Visible Light Transmittance (VLT) = 48% (GL) / 23% (GL-Plus) U-Value = 0.24 (GL) / 0.19 (GL with Low-E) / 0.19 (GL-Plus) Solar Heat Gain Coefficient (SHGC) = 0.43 (GL) / 0.24 (GL-Plus) STC Rating = Brings an improvement of 1-2 dB soundproofing
Testing:
Fire-retardant material with Euro class B1 test certificate
Potential Leed Credit:
EA Credit 1: Optimize Energy Performance
IEQ Credit 7.1: Thermal Comfort
IEQ Credit 8.1: Daylight & Views: Daylight 75% of Spaces
VIDEOS:
- time lapse exterior: https://www.youtube.com/watch?v=oNoA3E0ekIg
- interior and surrounds: https://www.youtube.com/watch?v=MlJOhufTyNU
- energy performance case study: https://www.youtube.com/watch?v=NNcp2PoktzI
- an architect's guide to channel glass: https://www.youtube.com/watch?v=fbFWjJ9W8fM
- laminated glass production: https://www.youtube.com/watch?v=p6ErImUdFeg